USA
USA
Canada
International
1600 Brittmoore Rd Houston, TX 77043, USA
180 Strathmoor Drive Sherwood Park, AB T8H 2B7
1600 Brittmoore Rd Houston, TX 77043, USA
Blackstone Technical Services

Alignment Interference Analysis

Project Overview

The customer attempted to install a new turbine, but the revised drain arrangement interfered with the existing baseplate, making installation impossible without significant modification.

Fig1 | Customer Identified Interference w/ baseplate & highlighted area of concern

 

Solution

Blackstone:

  • Performed 3D scans of both the in-service turbine and the new turbine, followed by a variation analysis of the piping arrangement.

  • Identified that three flanges were incorrectly located in addition to the required fitting change.

  • Replaced two drain spools to ensure proper alignment with the plant’s piping and baseplate constraints.

  • Added supports to the piping to maintain alignment and compliance with applicable API codes.

Fig 2 & 3 | Blackstone contracted to scan in-service & new turbines

 

Results

  • Avoided onsite piping modifications and eliminated the risk of pipe strain.

  • Enabled installation of the new turbine without requiring changes to the baseplate.

Fig 4 & 5 | Blackstone performed corrections and validated against scans

 

Contact us today to see how we can support your next project.